(1)
Plywood cladding shall be not less than 6 mm thick when applied directly to sheathing.
(2)
When applied directly to framing or over furring strips, plywood cladding thickness shall conform to Table 9.27.8.2.
(3)
The thickness of grooved or textured plywood cladding shall be measured at the point of least thickness.
Table 9.27.8.2. Minimum Plywood Cladding Thickness
Forming Part of Sentences 9.27.8.2.(2) and 9.27.10.2.(2)