8.7.2.2. Distribution Pipes within Leaching Beds

Feb 03, 2026© King's PrinterJan 16, 2025

(1)

Sentence (2) applies to the design and construction of a leaching bed with distribution pipes used within the leaching bed.

(2)

The header line and distribution pipes within a leaching bed shall be designed and constructed so that they can be detected by

(a)

magnetic means,

(b)

means of a 14 gauge TW solid copper light coloured plastic coated tracer wire, or

(c)

other means of subsurface detection.