(1)
Supply fittings shall conform to
(a)
ASME A112.18.1 / CSA B125.1, “Plumbing Supply Fittings,” or
(b)
CSA B125.3, “Plumbing Fittings.”
(2)
Except for lavatories in healthcare facilities, emergency eye washes, and emergency showers, supply fittings and individual shower heads shall have an integral means of limiting the maximum water flow rate to that specified in Table 7.2.10.6. (See Note A-7.2.10.6.(2))
Table 7.2.10.6.
(2.1)
Sentence (2) does not apply to a fixture located in a heritage building.
(3)
Reserved.
(4)
Reserved.
(5)
Reserved.
(6)
Waste fittings shall conform to ASME A112.18.2 / CSA B125.2, “Plumbing Waste Fittings.”
(7)
Manually operated valves of NPS 4 or less for use in plumbing systems shall conform to ASME A112.4.14 / CSA B125.14, “Manually Operated Valves for Use in Plumbing Systems.” (See Note A-7.2.10.6.(7))