(1)

Except as provided in Sentence (2) and elsewhere in this Part, materials and components, and their installation, shall conform to the requirements of the applicable standards in Table 5.9.1.1. where those materials or components are

(a)

incorporated into environmental separators or assemblies exposed to the exterior, and

(b)

installed to fulfill the requirements of this Part. (See Note A-5.9.1.1.(1))

(2)

The requirements for flame-spread ratings contained in thermal insulation standards shall be applied only as required in Part 3.

Table 5.9.1.1. Standards Applicable to Environmental Separators and Assemblies Exposed to the Exterior

Forming Part of Sentence 5.9.1.1.(1)

Notes to Table 5.9.1.1.:

(1) See Note A-Table 5.9.1.1.

(2) The of gypsum board shall be determined in accordance with CAN/ULC-S102, “Test for Surface Burning Characteristics of Building Materials and Assemblies,” in lieu of ASTM E84 “Surface Burning Characteristics of Building Materials”, as indicated in ASTM C1396 / C1396M “Gypsum Board.”

(3) The flame-spread rating of glass mat gypsum panels shall be determined in accordance with CAN/ULC-S102 “Test for Surface Burning Characteristics of Building Materials and Assemblies,” in lieu of ASTM E84, “Surface Burning Characteristics of Building Materials,” as indicated in ASTM

(4) For the purpose of compliance with Part 5, ASTM D3019 / D3019M, “Lap Cement used with Asphalt Roll Roofing, Non-Fibered, Asbestos-Fibered, and Non-Asbestos-Fibered,” applies only with respect to non-fibered and non-asbestos-fibered (Types I and II) of asphalt roll