(1)

Except as required in Sentence (4) and except as permitted in Subsection 3.8.3., every barrier-free path of travel shall provide an unobstructed width of at least 1 100 mm for the passage of wheelchairs.

(2)

Interior and exterior walking surfaces that are within a barrier-free path of travel shall

(a)

have no opening that will permit the passage of a sphere more than 13 mm in diam,

(b)

have any elongated openings oriented approximately perpendicular to the direction of travel,

(c)

be stable, firm and slip-resistant,

(d)

be bevelled at a maximum slope of 1 in 2 at changes in level not more than 13 mm, and

(e)

be provided with sloped floors or ramps at changes in level more than 13 mm. (See Note A-3.8.1.3.(2))

(3)

A barrier-free path of travel is permitted to include ramps, passenger elevators or other platform equipped passenger elevating devices to overcome a difference in level.

(4)

Every barrier-free path of travel less than 1 600 mm in width shall be provided with an unobstructed space not less than 1 800 mm in width and 1 800 mm in length located not more than 30 m apart. (See Note A-3.8.1.3.(4))

(5)

Where the headroom of an area in a barrier-free path of travel is reduced to less than 1 980 mm, a guardrail or other barrier with its leading edge at or below 680 mm from the finished floor shall be provided. (See Note A-3.8.1.3.(5) and (6)(b))

(6)

A normally occupied floor area that is not required by Article 3.8.2.1. to have a barrier-free path of travel shall meet the following requirements:

(a)

interior walking surfaces throughout the normally occupied floor area shall comply with Clauses (2)(a) to (e), and

(b)

where the headroom of an area in a corridor or aisle in the normally occupied floor area is reduced to less than 1 980 mm, a guardrail or other barrier with its leading edge at or below 680 mm from the finished floor shall be provided. (See Note A-3.8.1.3.(5) and (6)(b))