(1)

Except as provided in Sentence (2), an exterior balcony shall be constructed in accordance with the type of construction required by Articles 3.2.2.20. to 3.2.2.93., as applicable to the occupancy classification of the building.

(2)

The floor assembly of an exterior balcony in a building or part thereof conforming to Article 3.2.2.48., 3.2.2.57. or 3.2.2.93. shall

(a)

be of noncombustible construction, or

(b)

be constructed in accordance with Article 3.1.6.3., but need not comply with Sentence 3.1.6.4.(1).