(1)
Despite Sentences 3.11.3.1.(4) and (8) and Clause 3.11.3.1.(9)(a), where a public pool is constructed in a building containing a Group B, Division 2 or 3 major occupancy and has a water depth not exceeding 1 500 mm and a water surface area not exceeding 100 m
(2)
Despite Sentence 3.11.3.1.(26), a warning notice, on which are printed in letters at least 150 mm high the words CAUTION — NO DIVING, shall be posted conspicuously on each wall or fence line enclosing a pool described in Sentence (1).
(3)
There shall be a curb along the perimeter of a pool described in Sentence (1) except at steps, ladders and ramp entrances.
(4)
The curb required by Sentence (3) shall have
(a)
a height of 50 mm,
(b)
rounded edges,
(c)
a coved base, and
(d)
a raised nosing at the top to serve as a fingerhold for a bather in the water.