(1)
No major occupancy of Group F, Division 1 shall be contained within a building with any occupancy classified as Group A, B or C.
(2)
Except as provided in Sentence (4) and Sentence 3.10.2.4.(9), not more than one suite of residential occupancy shall be contained within a building classified as a Group F, Division 2 major occupancy.
(3)
A sleeping room or sleeping area shall not open directly into a room or area where food is intended to be stored, prepared, processed, distributed, served, sold or offered for sale. (See Note A-3.1.3.2.(3))
(4)
A Group F, Division 2 major occupancy is permitted in a building containing only work units if the occupancy is for the exclusive use of the occupants of the work units.
(5)
A building within the scope of Article 3.2.2.51. or 3.2.2.60. shall not contain a retirement home.