(1)

Exhaust ducts or vents connected to laundry-drying equipment shall discharge directly to the outdoors.

(2)

Exhaust ducts connected to laundry-drying equipment shall be

(a)

independent of other exhaust ducts,

(b)

accessible for cleaning, and

(c)

constructed of a smooth corrosion-resistant material. (See Note A-9.32.1.3.(2))

(3)

Where collective venting of multiple installations of laundry-drying equipment is used, the ventilation system shall

(a)

be connected to a common exhaust duct that is vented by one central exhaust fan, and incorporates one central lint trap,

(b)

include an interlock to activate the central exhaust fan when laundry-drying equipment is in use, and

(c)

where required by Article 9.32.3.8., be provided with make-up air.