(1)
A water service pipe intended to serve a mobile home shall
(a)
be not less than NPS ¾,
(b)
terminate above ground, and
(c)
be provided with
(i)
a tamperproof terminal connection that is capable of being repeatedly connected, disconnected and sealed,
(ii)
a protective concrete pad,
(iii)
a means to protect it from frost heave, and
(iv)
a curb stop and a means of draining that part of the pipe located above the frost line when not in use.