(See Note A-7.2.5.9. to 7.2.5.11.)
(1)
Solvent cement for transition joints shall conform to
(a)
CSA B181.1, “Acrylonitrile-butadiene-styrene (ABS) drain, waste, and vent pipe and pipe fittings,” or
(b)
CSA B181.2, “Polyvinylchloride (PVC) and chlorinated polyvinylchloride (CPVC) drain, waste, and vent pipe and pipe fittings.”
(2)
Transition solvent cement shall only be used for joining an ABS drainage system to a PVC drainage system.